Combination smoke and carbon monoxide alarms are convenient because they detect two different threats, fire and carbon monoxide, in a single device. But because they cover both, their placement needs to satisfy the guidelines for smoke detection and CO detection together. Placing them correctly ensures you get reliable protection against both hazards throughout your home.
Here is how to place combination smoke and carbon monoxide detectors.
Where combination alarms go
Combination alarms generally follow the placement that satisfies both smoke and CO requirements, which means installing them:
- Inside each bedroom
- Outside each separate sleeping area
- On every level of the home, including the basement
This layout covers the sleeping areas and every level for both fire and carbon monoxide, which is why combination alarms are a practical choice for these locations.
Height and mounting
Combination alarms are typically mounted on the ceiling or high on the wall, following smoke detector placement guidance. Smoke rises, so a high mounting position detects it early. Carbon monoxide mixes with air rather than strictly rising, so a high-mounted combination alarm still detects it effectively. Follow the manufacturer’s instructions for the specific mounting height and position of your unit.
Places to avoid
Just as important is where not to place a combination alarm, to avoid nuisance alarms and ensure reliable detection:
- Keep them a reasonable distance from kitchens and cooking appliances to reduce false alarms from cooking.
- Keep them away from bathrooms, where steam can cause nuisance alarms.
- Avoid dead air spaces, such as the very peak of a vaulted ceiling or tight ceiling corners.
- Follow the manufacturer’s guidance on distance from fuel-burning appliances, since being too close can cause CO nuisance alarms.
Carbon monoxide considerations
Because these alarms also detect carbon monoxide, keep the CO side of the equation in mind. Carbon monoxide comes from fuel-burning appliances, attached garages, and similar sources, so having combination alarms outside sleeping areas and on every level, including near but not too close to fuel-burning appliances per the manufacturer, provides good CO coverage. Maryland has its own carbon monoxide alarm requirements for certain dwellings, which apply alongside smoke alarm rules.
Keeping them working
To keep combination alarms effective:
- Test them about once a month using the test button.
- Replace smoke and combination alarms at the manufacturer’s recommended interval, commonly 10 years for the smoke function, and follow the unit’s guidance for the CO sensor life.
- Do not disable or remove them.
Combination smoke and carbon monoxide alarms should be placed to satisfy both smoke and CO guidelines: inside each bedroom, outside each sleeping area, and on every level of the home, mounted high per the manufacturer, and kept away from kitchens, bathrooms, dead air spaces, and too-close positions near fuel appliances. This placement gives you reliable protection against both fire and carbon monoxide. A licensed electrician can install combination alarms correctly throughout your home.